FinOps Meets GreenOps: Measuring Cloud Carbon Without Extra Instrumentation

You don't need new agents or sensors to understand your cloud carbon footprint. Here is how to get the official numbers from AWS, Google Cloud and Azure, estimate emissions from the usage data your FinOps practice already collects, and cut cost and carbon together.

Sustainability has moved from an annual report footnote to a procurement requirement. Customers ask for emissions data in vendor questionnaires, leadership sets reduction targets, and sustainability teams need numbers they can defend. Many engineering leaders assume this means a new monitoring project across every cluster.

It usually doesn't. Cloud carbon is driven by the same things as cloud cost: how much compute, storage and networking you use, where it runs and when. If you already track spend by team and service, you are most of the way to tracking carbon the same way, and most actions that cut one also cut the other.

Why cost and carbon belong in the same view

  • Shared drivers. Idle and oversized resources waste money and energy at the same time. Deleting an idle environment cuts both, so there is no separate GreenOps backlog to maintain.
  • Shared ownership. The accounts, tags and namespaces that attribute cost to teams attribute carbon to them too.
  • Visible trade-offs. Moving a workload to a lower-carbon region might cost slightly more, or less. With both numbers side by side, teams decide deliberately rather than by accident.

Two kinds of carbon data, for two jobs

Most confusion about cloud carbon comes from mixing up two different datasets. You need both.

Two carbon data paths Provider carbon tools feed monthly formal reporting. Usage-based estimates from billing data feed daily engineering decisions. The two are reconciled. REPORTING PATH (MONTHLY) Provider carbon tools AWS · Google Cloud · Azure Scope 1, 2 and 3 by account, service, region Formal reporting ESG · customer requests ENGINEERING PATH (DAILY) Billing & usage exports already used for FinOps Estimate emissions energy × PUE × grid intensity Team decisions next to cost, by service reconcile
Use provider figures for reporting, and usage-based estimates for the decisions engineers make every day.
  • Provider carbon tools are authoritative and include Scope 1, 2 and 3 emissions, so they are what you report. But they are monthly, arrive weeks after the month ends, and are summarised by account, service and region rather than by your teams.
  • Usage-based estimates are built from the detailed billing and usage data you already export. They are approximate, but available daily and at the level of individual teams and workloads, which is what engineers can act on.

Step by step: get the official numbers from each provider

AWS: the Sustainability console

In March 2026 AWS launched a dedicated, free AWS Sustainability console, expanding on the Customer Carbon Footprint Tool in the Billing console. It reports estimated emissions by Region, service and scope, using both location-based and market-based methods, with history back to January 2022.

  1. Grant the people or roles who need it the IAM permissions sustainability:GetEstimatedCarbonEmissions and sustainability:GetEstimatedCarbonEmissionsDimensionValues. Billing console access is no longer required.
  2. Open the Sustainability console and filter by account, Region, service and scope.
  3. Use the CSV reports or the API to bring the monthly figures into your own reporting, and set your fiscal-year start so totals match your reporting periods.

Full walkthrough, with an IAM policy, CLI and Python examples and a monthly S3 export: A Guide to the AWS Sustainability Console.

Google Cloud: Carbon Footprint export to BigQuery

  1. Make sure you have the Carbon Footprint Viewer or Billing Account Viewer role on the billing account.
  2. In the console, open Carbon Footprint, choose your billing account and select Data export.
  3. Choose the project for the export and select Create export. On the BigQuery Data Transfer Service page, check that the source is Google Cloud Carbon Footprint Exports, then save.
  4. Request a backfill if you want history. Data is available back to January 2021, and each month's data is exported on the 15th of the following month into a monthly partitioned table called carbon_footprint.

Then query it like any other BigQuery table. This shows the last 12 months by service and region:

SELECT
  usage_month,
  service.description AS service,
  location.region AS region,
  ROUND(SUM(carbon_footprint_total_kgCO2e.location_based), 1) AS kgco2e_location_based,
  ROUND(SUM(carbon_footprint_total_kgCO2e.market_based), 1)   AS kgco2e_market_based
FROM `your-project.your_dataset.carbon_footprint`
WHERE usage_month >= DATE_SUB(DATE_TRUNC(CURRENT_DATE(), MONTH), INTERVAL 12 MONTH)
GROUP BY usage_month, service, region
ORDER BY usage_month DESC, kgco2e_location_based DESC;

You pay normal BigQuery storage and query charges for the exported data. If your organisation uses VPC Service Controls, allow the BigQuery and BigQuery Data Transfer Service APIs.

Microsoft Azure: carbon optimization

  1. Assign the Carbon Optimization Reader role to the people who need the data.
  2. In the Azure portal, search for Carbon optimization. It shows emissions down to individual resources for the last 12 months, at no extra cost.
  3. Select Export to CSV for analysis in Excel or Power BI, or use the export APIs to send the data to your own storage on a schedule.

How usage-based estimates work

The method is simple enough to explain to a finance or sustainability colleague, which matters when you need them to trust the numbers. The open-source Cloud Carbon Footprint project, started by Thoughtworks, documents a widely used version of it:

average watts      = min watts + average CPU utilisation x (max watts - min watts)
energy (kWh)       = average watts x vCPU-hours / 1000 x data-centre overhead (PUE)
operational CO2e   = energy x grid carbon intensity of the region (gCO2e/kWh)
total CO2e         = operational CO2e + share of hardware (embodied) emissions
  • Usage comes from billing and usage exports, such as AWS Cost and Usage Reports: vCPU-hours, GB-months of storage, GB transferred.
  • Min and max watts per vCPU come from published benchmark data for each processor family. Where utilisation isn't available, Cloud Carbon Footprint assumes 50%.
  • PUE (power usage effectiveness) adds the data centre's cooling and power overhead. Cloud Carbon Footprint uses provider-specific values where published, and a default of 1.185 otherwise.
  • Grid carbon intensity depends heavily on the region and changes through the day. Providers such as Electricity Maps and WattTime publish it, including hour-by-hour figures.
  • Embodied emissions account for manufacturing the hardware, spread across its expected lifetime.

The Software Carbon Intensity (SCI) specification from the Green Software Foundation, published as the international standard ISO/IEC 21031:2024, builds on the same ideas and expresses the result per unit of work, for example per API request or per transaction. That makes it useful for comparing services and tracking efficiency as you grow.

Location-based and market-based numbers

Under the GHG Protocol, electricity emissions can be reported two ways. Location-based figures use the average intensity of the local grid. Market-based figures reflect the renewable energy your provider buys, and often look much lower. For engineering decisions about where and when to run work, location-based figures are usually more useful. Whatever you show, label which one it is.

See carbon next to spend, by team

Aavya Optima estimates emissions from your existing multi-cloud usage data and shows them alongside cost for every team and service.

Try Aavya Optima free

Four ways to reduce both cost and carbon

1. Remove waste first

Idle staging environments, unattached volumes, old snapshots and forgotten load balancers draw power and money continuously. Removing them needs no trade-off discussion.

2. Choose regions with carbon in mind

Grid carbon intensity can differ several-fold between regions. Regions on largely hydro and nuclear grids, such as Stockholm (eu-north-1) or Canada Central (ca-central-1), typically have far lower intensity than coal-heavy grids. Check current figures in Electricity Maps before deciding. As an illustration, a workload using 10,000 kWh a month emits about 4 tonnes CO2e on a grid averaging 400 gCO2e/kWh, and about 0.5 tonnes on one averaging 50 gCO2e/kWh. For new workloads without strict data-residency or latency constraints, include carbon intensity in the region decision.

3. Shift flexible work in time

Batch jobs, model training, ETL, reports and backup verification can often run when the grid is cleaner, for example when solar or wind output is high. Hour-by-hour intensity data makes this schedulable, just as off-hours scaling saves money.

4. Get more work per watt

Newer-generation and ARM-based instances often deliver more work for the same energy. AWS, for example, states that Graviton-based instances use up to 60% less energy than comparable EC2 instances for the same performance. Results depend on the workload, so benchmark yours before migrating.

Make it part of the FinOps routine

WhereAdd carbon
Monthly cost review by teamEmissions trend per team and service, with the same attribution
Rightsizing and cleanup recommendationsEstimated CO2e saved next to dollars saved
Architecture and region decisionsGrid intensity of the candidate regions
Formal reportingProvider figures, reconciled with your estimates

Done this way, GreenOps stops being a separate initiative competing for engineering time. It becomes one more column in decisions teams already make.

Cut cloud spend and carbon together

Use Aavya Optima on its own, or work with our engineers to build cost and carbon guardrails into your infrastructure-as-code and pipelines.

Try Aavya Optima free   FinOps & GreenOps services

Sources and further reading

Lalit Kumar

Director, Founder & CTO of NeoAavya Consulting Services. A solution architect with 16 years of industry experience, Lalit leads NeoAavya’s technology, including the engineering behind Aavya Optima.

More about Lalit and his articles   Connect on LinkedIn

Read next